1 / 2
XH-W3005 W3005 DC 24V  10A Digital Humidity Controller Hygrometer Control Switch 0~99%RH Hygrostat w/ Humidity Sensor – KSH 1,500 at HIMASTORES Mombasa – best electronics in Kenya
XH-W3005 W3005 DC 24V  10A Digital Humidity Controller Hygrometer Control Switch 0~99%RH Hygrostat w/ Humidity Sensor – KSH 1,500 at HIMASTORES Mombasa – best electronics in Kenya - View 2

XH-W3005 W3005 DC 24V 10A Digital Humidity Controller Hygrometer Control Switch 0~99%RH Hygrostat w/ Humidity Sensor

SKU: HMJ1050 Category: HIMA electronics
KSH 1,500.00
Out of Stock

Product Description

XH-W3005 DC 24V 10A Digital Humidity Controller

Professional Humidity Control for 24V Systems

The XHW3005 DC 24V is a highperformance digital humidity controller designed for 24V DC systems with 0~99% RH measurement and 10A relay output. This hygrostat provides precise automatic control for humidifiers, dehumidifiers, and ventilation systems with its built-in sensor and large LCD display.

Built-in sensor with ±3% RH accuracy
Compatible with HUM and DEH operating modes
Rated for 24V DC 10A max - do not exceed

Technical Specifications

ParameterValue
ModelXH-W3005 (W3005)
Power Supply24V DC
Relay Output10A (resistive load)
Humidity Range0 ~ 99% RH
Measurement Accuracy±3% RH
Temperature Range-40°C ~ 120°C
Sensor TypeBuilt-in digital sensor
DisplayLarge LCD with backlight
Power Consumption< 3W
Working Temperature-10°C ~ 60°C
Dimensions80 x 55 x 35 mm

= Key Features =

High Precision - ±3% RH accuracy for reliable control

Dual Mode - Switchable HUM/DEH operation

Large LCD Clear realtime humidity and temperature readings

10A Relay Direct control of highpower 24V devices

Wide Range - 0~99% RH adjustable setpoint

Memory Function - Retains settings after power loss

Temperature Display - Shows current temperature alongside humidity

Compact Design Spacesaving form factor

= Applications =

  • Mushroom cultivation and growing rooms
  • Greenhouse and agricultural environments
  • HVAC systems and climate control
  • Seed germination and plant propagation
  • Home wine cellars and cigar humidors
  • Industrial storage and warehouses
  • Museum and archival preservation
  • Food processing and storage facilities
  • Laboratory and clean room environments
  • 24V automotive and marine applications

How to Set Up

  1. Connect 24V DC to power input terminals (+/-)
  2. Wire load to relay output (COM/NO/NC)
  3. Power on and select HUM or DEH mode
  4. Set desired humidity level using UP/DOWN buttons
  5. Adjust hysteresis if needed (default 3% RH)
Default hysteresis is 3% RH to prevent rapid cycling
For critical applications, set to 1% for tighter control
Use qualified electrician for permanent installation

Modes Explained

HUM Mode: Relay activates when humidity falls below setpoint (humidifier runs)

DEH Mode: Relay activates when humidity rises above setpoint (dehumidifier runs)


Important Settings

ParameterRangeDefault
Setpoint (H/S)0-99% RH50%
Mode (COD)HUM/DEHHUM
Hysteresis (DIF)0.1-9.9%3.0%
Calibration (CAL)±9.9%0.0%

= Calibration Instructions =

Press and hold SET for 5 seconds to enter menu, navigate to CAL parameter, adjust offset to match reference hygrometer, press SET to save.

Positive offset (+) increases displayed reading
Negative offset (-) decreases displayed reading
Calibrate annually or when accuracy issues arise

What's Included

  1. XH-W3005 DC 24V Controller
  2. Built-in Humidity Sensor
  3. Mounting Brackets with Screws
  4. User Manual

Why Choose XH-W3005 DC 24V?

±3% RH accuracy for reliable humidity control
Dedicated 24V DC power input for mobile and industrial systems
Dual humidification and dehumidification modes
Simple operation with intuitive interface
Versatile applications across industries
Costeffective professionalgrade solution

√ Ready to use out of the box with pre-calibrated sensor

√ Large LCD for easy reading in any condition

√ Memory retains settings during power interruptions

√ 10A relay capacity for direct load control

√ Compact design fits in standard electrical panels


Safety Precautions

Installation by qualified personnel only
Disconnect power before wiring connections
Do not exceed 10A current rating
Keep away from water splashes and direct sunlight
Do not use in explosive or flammable environments
Ensure proper ventilation around controller
Do not attempt to open or modify the unit
Verify correct polarity when connecting 24V DC
For loads exceeding 10A, use an external contactor or relay
Install at least 2 meters above floor level for best sensor performance

Avoid installing in areas with chemical vapors or condensation


Troubleshooting Common Issues

"ERR" or "-" display - Sensor connection issue or sensor failure
Relay not switching - Check power supply and wiring connections
Inaccurate reading - Perform CAL adjustment or relocate sensor
Blank display - Check 24V DC power input and polarity
Relay clicking rapidly - Increase hysteresis (DIF) setting
Cannot change settings - Press and hold SET for 5 seconds
For "ERR" error, try resetting by power cycling the unit
If problems persist, contact our support team

Compatibility Guide


Device TypeCompatibility
24V DC Humidifiers√ Yes (within 10A)
24V DC Dehumidifiers√ Yes (within 10A)
24V Ventilation Fans√ Yes (within 10A)
24V Misting Systems√ Yes (within 10A)
24V Heating Elements√ Yes (within 10A)
Automotive Systems√ Yes (12V-24V compatible)

= Quick Reference: Default Factory Settings =

SettingValue
Humidity Setpoint50% RH
Control ModeHUM (Humidification)
Hysteresis3.0% RH
Calibration Offset0.0% RH
Delay Time0 minutes

? Adjust these settings to suit your specific application requirements

Maintenance Tips

√ Clean unit surface with dry cloth only - do not use liquids

√ Check wiring connections periodically for tightness

√ Verify humidity reading against reference hygrometer every 6 months

√ Keep sensor area free from dust and debris

√ Test relay function periodically


Quick Comparison: 24V vs 220V Versions


Feature24V DC Version220V AC Version
Power Input24V DC90-240V AC
Best ForAutomotive, marine, solar systemsHome, industrial AC power
SafetyLow voltage, safer handlingStandard mains voltage
Relay Rating10A @ 24V DC10A @ 220V AC

Choose the XHW3005 DC 24V for reliable humidity control in lowvoltage systems! Whether you're automating a greenhouse, protecting valuable equipment, or managing climate in mobile applications, this controller delivers professional-grade performance with the safety of 24V DC operation.

XHW3005 W3005 24V DCHUMIDITYCONTROLLER HYGROSTAT LOWVOLTAGE CLIMATECONTROL AUTOMATION HUMIDIFICATION MUSHROOMGROWING GREENHOUSE SOLARPOWER MARINE AUTOMOTIVE New Best Seller 24V